Red Lion RL-SPRK150 Sprinkler/Irrigation Pump, 115/230V, 71 GPM, 1.5 HP | Thermoplastic Impeller, For water sources down to 25' deep, Handles up to 14 sprinklers (1/2" fittings) per zone, 97101501
BUILT TO LAST: Rugged cast iron pump housing and glass-filled thermoplastic impeller for well water and lake water
DUAL VOLTAGE MOTOR: select 115 Volts or 230 Volts to match incoming power source; factory set to 230 Volts but easy to switch to 115 Volts (see manual)
ONE-TIME PRIMING: No additional priming is required after initial fill; follow the priming instructions in the owner's manual
UP TO 63 GPM at 10 PSI: 38 GPM at 30 PSI - can handle up to 12 sprinkler heads with 1/2-inch fittings or 6 sprinkler heads with 3/4-inch fittings in each zone
RL-SPRK100 115/230 Volt, 1 HP 63 GPM Cast Iron Sprinkler/Irrigation Pump with Thermoplastic Impeller
Maximum Flow Rate
63 gpm
Power Source Type
Corded Electric
Included Components
Installation manual, Pump with thermoplastic impeller
Maximum Lifting Height
25 feet
Item Length Width Height
21.85"L x 11.42"W x 10.2"H
Manufacturer Part Number
97101001
Item Dimensions L x W x H
21.85"L x 11.42"W x 10.2"H
Specific Uses For Product
Amateur, Professional
Manufacturer Warranty Description
2 year manufacturer
Global Trade Identification Number
00010121001398, 00010121124868
Red Lion RL-SPRK100
1 HP Sprinkler/Irrigation Pump
The RL-SPRK100 is designed for residential multiple sprinkler head irrigation systems and can handle up to 12 SPRINKLER HEADS with 1/2" fittings per zone or 6 sprinkler heads with 3/4" fittings per zone. This pump delivers 38 GPM at 30 PSI at 5' lift with a maximum pressure of 45 PSI.
RL-SPRK100 1 HP Sprinkler Pump Technical Specifications
Motor
1 HP open, drip-proof, thermally protected motor
Voltage
Dual voltage (115/230-volt); comes factory-set for 230-volt operation but can be easily switched to 115-volt operation; voltage of pump must match voltage of power source as motor can be seriously damaged
Amperage
14 running Amps at 115V; 7 running Amps at 230 Volts
Wattage
4848 Watts
Intake
2" FNPT
Discharge
1-1/2" FNPT
Performance @ 10 psi (5' lift)
63 gpm
Performance @ 20 psi (5' lift)
54 gpm
Performance @ 30 psi (5' lift)
38 gpm
Performance @ 40 psi (5' lift)
11 gpm
Number of sprinklers supported
12 sprinkler heads with 1/2" fittings @ 30 psi per zone; 6 sprinkler heads with 3/4" fittings @ 30 psi per zone
Maximum pressure
45 psi
Materials
Cast iron casing; thermoplastic impeller
Product Selection Tips:
The easiest way to select the proper pump for the job is to determine how many sprinkler heads and what size pipe is used. If 1/2" pipe is used, the formula is GPH at 30 PSI divided by 3. If 3/4" pipe is used, the formula is GPH at 30 PSI divided by 6. We have done the calculations for you and the information can be found in both the technical specifications and the pump comparison chart found on this page.
Installation Tips:
This pump is rated 4 out of 5 stars in level of difficulty (5 being most difficult). Electrical wiring is required along with precise measurements for cutting the piping. This pump is designed to work with a pump start relay and a timer (not included.) We strongly recommend hiring a sprinkler pump installer or contractor with sprinkler installation experience for this installation.
This pump is DUAL VOLTAGE which means it will work with both 115 Volt and 230 Volt power sources. The voltage selection indicator on the pump MUST MATCH the power source. The pump comes PRE-SET for 230 Volt operation. To use the pump for 115 Volt installation, the voltage indicator on the pump must be changed to 115 Volts. Instructions for changing the voltage are in the Owner's Manual. A small motor cover is located on the back end of the pump's motor and must be removed with a screwdriver. For the 1 HP model, once the cover is removed, insert a flat head screwdriver in the voltage change indicator and rotated counter clockwise so it read 115 and replace the motor cover. (See Owner's Manual for illustration.)
USE PTFE tape on all pipe thread and ensure the the suction and discharge lines are completely AIRTIGHT otherwise the pump will lose prime and will be extremely noisy (called cavitation).
PRIME the pump! Remove the priming port plug at the top of the unit. Open the discharge valves on the discharge side of the pump. Fill the pump with water through the priming port. Allow trapped air to escape for a few minutes, then add more water until the pump and line is full. Replace the priming port plug and tighten with a wrench.
A CHECK VALVE (not included) should be installed on the discharge line to keep the pump primed and a STRAINER should be used on the intake line to keep debris from entering the pump.
Additional instructions, safety tips, and troubleshooting tips are found in the Owner's Manual.